Varec 2920 Installation And Operation Manual page 76

Float & tape transmitter
Table of Contents

Advertisement

2920 Float & Tape Transmitter
66
Display Only
Temp
Raw Value
Resistance
Value1
Value2
Value3
100 Ohm RefRes
200 Ohm RefRes
Temp Dis Units
Pnt Status
Elapse
Pnt Checksum
Command
Cal. Command
Description
Measured temperature in degrees.
Un-calibrated resistance measurement value.
Calibrated Resistance measure value. The Value used to
calculate the actual temperature parameter.
Parameters used in ratio metric resistance
measurement.
Parameters used in ratio metric resistance
measurement.
Parameters used in ratio metric resistance
measurement.
24-bit value representing the ratio metric value of a
100-ohm precision reference resistor.
24-bit value representing the ratio metric value of a
200-ohm precision reference resistor.
Indicates the temperature units that have been set to
display temperature on the LCD. Set in Basic Setup.
RTD PntStatus values:
0x0001 - RTD Temperature Invalid
0x0002 - Resistance is below table value (Under Range -
RTD may be shorted)
0x0004 - Resistance is above table value (Over Range -
RTD may be opened)
0x0008 - RTD is uncalibrated
0x0010 - Hardware Failure
Time of last update
CRC-16 Checksum of point's static configuration
parameters.
Parameter used to activate calibration parameters.