2920 Float & Tape Transmitter
90
Display Only
Avg Temp
Vap Temp
Elem #00
Elem #01 through #16
Elem #17
Meas Level
Status
Diag Code
Univ Cmd Rev
Dev Cmd Rev
Softw. Version
Hardw. Version
Cmd Status
Cmd Error
Comm. Tries
Comm. Fails
Elapse
Pnt Status
Pnt CheckSum
Command
Level
Command
Scan Cmd
Description
Average temperature
Average vapor temperature
Temperature conversion value of internal precision
Ohm
100
resistor.
Temperature measured by element #1 thrrough
element #16
Temperature conversion value of internal precision
Ohm
200
resistor.
The liquid level used for the average temperature
calculations, it is automatically updated by the 2920 to
be the actual measured level.
Status code of the NMT.
When the NMT electronics detect an error this
parameter shows the error code detected.
Revision of the universal command set the NMT
supports.
Revision of the device commands that the NMT
supports.
The software version of the NMT.
The hardware version of the NMT.
The status of command, as follows:
• Start
• Complete
• Error
The number of error if Command fails.
The number of times the 2920 has polled the NMT.
The number of time the communications from the 2920
to the NMT has failed.
Time of last update.
Byte value indicating status of point. Values are:
0: No error
CRC-16 Checksum of point's static configuration
parameters.
The measure level sent from the 2920 to the NMT.
The current command sent to the NMT.
The command used to set the type of scanning used by
the 2920 - Controlled by the application.