6.Parametersettingandfunctions
(3)RMSdisplay
This unit measures and displays RMS for accuracy.
At pure resistance load, in normal control, when input is 4-20mA and rating is 220V, it displays as
below.
Input
MV
Display
voltage
In case of static voltage or static current, voltage and current displays as below.
Input
MV
Display voltage
(static voltage control)
Display voltage
(static current control)
28
4mA
8mA
0%
25%
0.0V
70V
4mA
0%
0.0
0.0
12mA
50%
155.5V
8mA
12mA
25%
50%
55.0
110.0
12.5
25.0
©CopyrightReservedAutonicsCo.,Ltd.
16mA
20mA
75%
100%
209.7V
220.0V
16mA
20mA
75%
100%
165.0
220.0
37.5
50.0