Loadresistancedisplaymethod[ Dres ] - Autonics DPU Series User Manual

1-phase digital thyristor unit
Hide thumbs Also See for DPU Series:
Table of Contents

Advertisement

6.Parametersettingandfunctions
6.2.14
Loadresistancedisplaymethod[ DRES ]
This function is for display load resistance [ RES ] into a percentage in monitoring mode when
disconnecting the parallel load. You can select this value as increase rate of load resistance [ UP ]
or as decrease rate of number of loads [ DOWN ].
Decrease rate of number of loads [ DOWN ] displays correct decrease rate only when the connected
each load resistance is same.
R
to R
= 10Ω of each and load resistance (R) =1Ω
1
10
When disconnecting R
R
① Increase rate of load resistance [ UP ]
It is based on 100% of load resistance(R), 1Ω . When disconnected R
2Ω and load resistance [ RES ] in monitoring mode displays 200%.
② Decrease rate of number of loads [ DOWN ]
It is based on 100% of 10 loads (R
are 5(R
6
40
to R
,
1
5
R
R
1
2
to R
) and load resistance [ RES ] in monitoring mode displays 50%.
10
R
R
9
10
to R
). When disconnected R
1
10
to R
, load resistance is
1
5
to R
, the number of load
1
5
©CopyrightReservedAutonicsCo.,Ltd.