5.3.3
OperationMode[ OP ]
RUN
mode
Press
for 3 sec.
Operating
OP
mode
ST-T
Soft start time
S-LM
Start limit
S-LT
Start limit time
Output slope
A-GA
manual
adjustment
SLOP
Output slope
B-UP
Base up
UP-T
Slow up
DN-T
Slow down
Output low-limit
L-OL
value
Output high-limit
H-OL
value
C-LM
Current limit
SP1
Setting point 1
SP2
Setting point 2
SP3
Setting point 3
SP4
Setting point 4
SP5
Setting point 5
SP6
Setting point 6
Proportional
P
constant
Integral
I
constant
©CopyrightReservedAutonicsCo.,Ltd.
※ 1.
: Press any key among
P
※ To return RUN mode, press the
: This parameter may or may not appear, depending on the other parameter settings.
key
Displays operating mode.
※ 1
Set soft start time.
P
50
• Set range : 0 to 100sec
Set limit output value.
• Set range : 0 to 110%
Set start limit time.
• Set range : 0 to 100sec
Set output slope manual adjustment.
Set output change ratio by control input.
• Set range : 0.00 to 1.00%
※ Not displayed when output slope manual adjustment [ A-GA] is ON.
Set base-up value.
• Set range : 0 to 100%
Set slow-up time.
• Set range : 0 to 999sec
※ Not displayed when C-MD mode is set as cycle control.
Set slow-down time.
• Set range : 0 to 999sec
※ Not displayed when C-MD mode is set as cycle control.
Set output low-limit.
• Set range : 0 to 110%
Set output high-limit.
• Set range : 0 to 110%
Set current limit value.
• Set range : 0 to 110%
• Set range : 0 to 100%
※ Displayed only when DI-1 to DI-3 of ST-1 mode is set SP-M or SP1 to SP3.
• Set range : 0 to 100%
※ Displayed only when DI-1 of ST-1 is set SP-M.
Set proportional constant.
• Set range : 1 to 2000
※ Displayed only for static voltage, static current, static power in phase control.
Set integral constant.
• Set range : 0.1 to 999.9
※ Displayed only for static voltage, static current, static power in phase control.
5.Installationandinitialoperation
,
.
key at any parameter, or not to operate any keys in 30sec.
ON
OFF
23