Autonics DPU Series User Manual page 16

1-phase digital thyristor unit
Hide thumbs Also See for DPU Series:
Table of Contents

Advertisement

2.Specifications
Communicationspecifications
Application standard
Max. connections
Communication type
Synchronization method
Communication distance
Communication speed
Communication response time
Start bit
Data bit
Parity bit
Stop bit
Protocol
16
Compliance with EIA RS485
64 channels(address : 01 to 64, auto set)
2-wire half duplex
Asynchronous
Max. 800m
38,400 bps
5 to 99ms
1bit (fixed)
8bit (fixed)
None(fixed)
2bit(fixed)
ModBus RTU( ※ 1 character = fixed 11bit)
©CopyrightReservedAutonicsCo.,Ltd.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Digipower 2000

Table of Contents