PROGRAMMING MANUAL
12. PROGRAM PARAMETER
-5-14
NR. PARAMETER
»
FOOT PRESSURE CONTROL
INFO!
Automatic foot pressure control
On conventional machines the foot pressure is generated by a spring and will be adjusted seldom. The VETRON also generates
the foot pressure with a spring, but the spring is pre-stressed by a step motor with gear (parameter 050). In di erent programs
can di erent foot pressure be applied. You have the choice between three operation modes (parameter 054).
Operation mode: 1 = OFF
2 = CONSTANT
3 = 1-100%
INFO!
When sewing operation are done where the foot pressure is used to keep the material in position (e.g. piping) it is advisable
to use operation mode 1 (OFF). Operation mode 2 (CONSTANT) will lead to a negativ result. The material thickness recognition
will prevent positioning the piping.
050 Foot pressure
054 Dynamic foot pressure
20 PROGRAMMING MANUAL VETRON 5000
DESCRIPTION
Foot pressure is generated like on a conventional machine.
Can be di erent depending on the program.
The foot pressure will be constant on all material thicknesses. The material thickness recog-
nition will make sure that the foot pressure control that you have a constant foot pressure.
The foot pressure will be increased with increased sewing speed. Low percentage will
increase the pressure only weak. High percentage will increase the pressure stronger.
You will set the foot pressure for the program here. Comparable like on
a conventional machine.
The following functions are available:
Function 1 = OFF
Function 2 = CONST
Function 3 = %