Additional Resources; General Precautions - Allen-Bradley PowerFlex 70 Reference Manual

Adjustable frequency ac drives
Hide thumbs Also See for PowerFlex 70:
Table of Contents

Advertisement

Preface

Additional Resources

General Precautions

10
These documents contain additional information concerning related products
from Rockwell Automation.
Resource
PowerFlex 700 Standard Control User Manual,
publication
20B-UM001
PowerFlex 70 AC Drive Technical Data, publication
20A-TD001
PowerFlex 700 AC Drive Technical Data, publication
20B-TD001
PowerFlex Comm Adapter Manuals, publication
20COMM-UM...
PowerFlex 70 Enhanced Control and PowerFlex 700
Vector Control Reference Manual, publication
PFLEX-RM004
Wiring and Grounding Guidelines for Pulse Width
Modulated (PWM) AC Drives, publication
Safety Guidelines for the Application, Installation and
Maintenance of Solid State Control, publication
Guarding Against Electrostatic Damage, publication
8000-4.5.2
You can view or download publications at
http:/www.rockwellautomation.com/literature/. To order paper copies of
technical documentation, contact your local Allen-Bradley distributor or
Rockwell Automation sales representative.
ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts
!
and assemblies. Static control precautions are required when installing, testing,
servicing or repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with static control
procedures, reference A-B publication 8000-4.5.2, "Guarding Against
Electrostatic Damage" or any other applicable ESD protection handbook.
ATTENTION: An incorrectly applied or installed drive can result in component
!
damage or a reduction in product life. Wiring or application errors, such as,
undersizing the motor, incorrect or inadequate AC supply, or excessive ambient
temperatures may result in malfunction of the system.
ATTENTION: Only qualified personnel familiar with adjustable frequency AC
!
drives and associated machinery should plan or implement the installation,
start-up and subsequent maintenance of the system. Failure to comply may
result in personal injury and/or equipment damage.
ATTENTION: To avoid an electric shock hazard, verify that the voltage on the
!
bus capacitors has discharged before performing any work on the drive.
Measure the DC bus voltage at the +DC & –DC terminals of the Power Terminal
Block (refer to the Installation Instructions for location). The voltage must be
zero.
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013
Description
Provides detailed information on:
• Parameters and programming
• Faults, alarms, and troubleshooting
This publication provides detailed drive specifications,
option specifications and input protection device ratings.
These publications provide information on configuring,
using, and troubleshooting PowerFlex communication
adapters.
These publications provide detailed application specific
information for programming and configuring the
PowerFlex 700 drive.
Provides basic information needed to properly wire and
DRIVES-IN001
ground PWM AC drives.
Provides general guidelines for the application,
SGI-1.1
installation, and maintenance of solid-state control.
Provides practices for guarding against Electrostatic
damage (ESD)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerflex 700

Table of Contents