Advertisement

5-0
StartUp
5. Speed Control
Enter
This section
defines a source
5-1
from which to control
speed.
StartUp
5. Speed Control
Enter choice for
Speed Control
<Analog Input>
Adapter
Comm Adapter
Local HIM-Port 1
Remote HIM
Preset Speeds
MOP
5-2
StartUp
5. Speed Control
Enter choice for
Comm Adapter
Port 5-internal
Port 2-external
Port 3-external
Remote
Enter
HIM
Go to 0-1 (6)
Enter
5-3
StartUp
5. Speed Control
Enter choice for
Remote HIM
Port 2 (common)
Port 3
5-4
StartUp
5. Speed Control
Enter/
Enter value for
Backup
Preset Speed 1
5.0 Hz
xxx.x < yyy.y
Preset
5-5
Speed 1
StartUp
5. Speed Control
Enter value for
Preset
Preset Speed 2
Speed 2
10.0 Hz
xxx.x < yyy.y
5-6
Preset
StartUp
Speed 3
5. Speed Control
Enter value for
Preset
Preset Speed 3
Speed 4
15.0 Hz
xxx.x < yyy.y
5-7
5-8
StartUp
StartUp
5. Speed Control
5. Speed Control
Enter value for
Enter value for
Preset Speed 4
Preset Speed 5
20.0 Hz
25.0 Hz
xxx.x < yyy.y
xxx.x < yyy.y
Figure 45 PowerFlex 70 & 700 Standard Control Option Startup (5)
MOP
Local HIM-
Port 1
Go to 0-1 (6)
Preset
Speeds
5-11
StartUp
5. Speed Control
Note: Factory default
settings
provide preset
speed operation
from the digital
inputs, unless
you change
their function.
Enter
5-12
StartUp
5. Speed Control
Make a selection .
<Preset Speed 1>
Preset Speed 2
Preset Speed 3
Preset Speed 4
Preset Speed 5
Preset Speed 6
Preset Speed 7
Done
Done
Preset
Preset
Preset
Speed 5
Speed 6
Speed 7
5-9
StartUp
5. Speed Control
Enter value for
Preset Speed 6
30.0 Hz
xxx.x < yyy.y
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013
Analog Input
5-14
5-18
StartUp
StartUp
5. Speed Control
5. Speed Control
Digital Inputs
Enter choice for
5 & 6 will be
Signal Type
set to MOP Inc &
Voltage
MOP Dec.
Current
Enter
5-15
5-19
StartUp
StartUp
5. Speed Control
5. Speed Control
Save MOP speed
The next two
at power down ?
parameters link
<Yes>
a high speed
No
with a high
analog value.
5-20
Enter
5-16
StartUp
StartUp
5. Speed Control
5. Speed Control
Enter value for
Save MOP speed
Analog In 1 Hi
at stop ?
10.0 V
<Yes>
xxx.x < yyy.y
No
5-21
Enter
StartUp
5-17
5. Speed Control
PF70 StartUp
Enter value for
5. Speed Control
Speed Ref A Hi
Enter value for
60.0 Hz
MOP Rate
xxx.x < yyy.y
5.0 Hz
xx.x < yy.y
5-22
StartUp
5. Speed Control
The next two
Enter
parameters link
a low speed
with a low
analog value.
Go to 0-1 (6)
5-23
StartUp
5. Speed Control
Enter value for
Analog In 1 Lo
Enter
0.0 V
xxx.x < yyy.y
5-10
5-24
StartUp
StartUp
5. Speed Control
5. Speed Control
Enter value for
Enter value for
Preset Speed 7
Speed Ref A Lo
35.0 Hz
xxx.x < yyy.y
0.0 Hz
xxx.x < yyy.y
Start-Up
Basic Start Up (Speed Control)
5-13
StartUp
5. Speed Control
Enter choice for
Input Signal
Analog Input 1
Analog Input 2
Analog
Analog
Input 1
Input 2
5-24
5-25
StartUp
5. Speed Control
Enter choice for
Signal Type
Voltage
Current
Enter
Enter
5-26
StartUp
5. Speed Control
The next two
parameters link
a high speed
with a high
analog value.
Enter
Enter
5-27
StartUp
5. Speed Control
Enter value for
Analog In 2 Hi
10.0 V
xxx.x < yyy.y
Enter
Enter
5-28
StartUp
5. Speed Control
Enter value for
Speed Ref A Hi
60.0 Hz
xxx.x < yyy.y
Enter
Enter
5-29
StartUp
5. Speed Control
The next two
parameters link
a low speed
with a low
analog value.
Enter
Enter
5-30
StartUp
5. Speed Control
Enter value for
Analog In 2 Lo
0.0 V
xxx.x < yyy.y
Enter
Enter
5-31
StartUp
5. Speed Control
Enter value for
Speed Ref A Lo
0.0 Hz
xxx.x < yyy.y
183