Allen-Bradley PowerFlex 70 Reference Manual page 187

Adjustable frequency ac drives
Hide thumbs Also See for PowerFlex 70:
Table of Contents

Advertisement

1-0
B
1-1
Start-Up
Start-Up
1. Motor Control
1. Motor Control
This section
Make a selection
selects the type
<1.SVC>
of Motor Control
2.V/Hz
the drive will
3.Flux Vector
use.
4.More info
SVC- Set
#53= 0
1-2
B
Start-Up
SVC
Enter choice of
Speed Units
<Hz>
RPM
1-3
Start-Up
SVC
Enter choice for
Slip Comp
<Enable>
Disable
Disable
Enable
Set #80=0
Set #80=1
1-4
1-5
Start-Up
Start-Up
SVC
SVC
Control selected
Control selected
is SVC with
is SVC with
no Slip Comp
Slip Comp
1-12
Start-Up
Flux Vector
Control selected
is Torque/FOC
Min Torque/Speed
Figure 49 PowerFlex 700 Vector Control Option Startup (1)
Frequency
1-17
Start-Up
1.Motor Control
More
Use SVC
info
Flux
for applications
Vector
requiring speed
1-6
B
regulation.
Use V/Hz control
Start-Up
for Fan/Pump and
Flux Vector
other V/Hz
NOTE! An Encoder
applications.
is required for
Use Flux Vector
the Flux Vector
for applications
Control option.
requiring Torque
control or tight
speed regulation.
1-7
B
Start-Up
Flux Vector
Enter value for
Encoder PPR
1024
B
1-8
Start-Up
Flux Vector
Enter choice of
B
Speed Units
<Hz>
RPM
1-9
Start-Up
Flux Vector
Enter choice of
Regulation
<Speed>
Torque
Torque path
1-10
Start-Up
Flux Vector
Select Torque
Regulate option:
<1.Torque Regul.>
2.Min Torque/Spd
3.Max Torque/Spd
4.Sum Torque/Spd
Min Torque/
5.Absolute
Speed -
Set #88 =3
Sum Trq/Speed-
Trq
Max
Regulate
Trq/Speed -
Set #88
Set #88 = 4
= 2
1-13
Start-Up
Start-Up
Flux Vector
Flux Vector
Control selected
Control selected
is Torque/FOC
is Torque/FOC
Max Torque/Speed
Torque Regulate
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013
B = Basic mode
1-18
Start-Up
V/Hz
Select a V/Hz
control option:
<1.V/Hz-Fan/Pump>
2.V/Hz-Cust/Std.
3.More info
Fan/Pump-Set #53=3
1-19
Start-Up
V/Hz
Enter choice for
Slip Comp
<Enable>
Disable
Disable
Set #80=0
Enable
Set #80=1
1-21
Start-Up
V/Hz
Control selected
is Fan/Pump
with Slip Comp
Speed path-
Set #88 to 1
1-11
B
Start-Up
Flux V ector
Control selected
is FOC Speed
Regulate.
1-16
Start-Up
Absolute-
Flux Vector
Set #88
Control selected
= 6
is Torque/FOC
Absolute
Set #88 = 5
1-15
Start-Up
Flux Vector
1-14
Control selected
is Torque/FOC
Sum Torque/Speed
2. Motr Dat/Ramp
Flux Vector Start Up (Motor Control Select)
Start-Up
1-31
V/Hz
The Fan/Pump
option selects a
predefined V/Hz
curve.
The Custom/Std.
option allows
you to define a
More
V/Hz curve or
info
select a default
V/Hz curve.
V/Hz
Custom/Std.
1-32
Start-Up
Start-Up
V/Hz
V/Hz
Define Custom
Enter choice for
Yes
V/Hz curve?
Slip Comp
<Yes>
<Enable>
No
Disable
Standard-
set params #54
& 69-72 to
default values
B
1-20
Start-Up
V/Hz
Start-Up
Enter value for
V\Hz
Run Boost
Control selected
10V
is Standard V/Hz
xx.x < yy.y
1-22
Start-Up
Start-Up
V/Hz
V/Hz
Enter value for
Control selected
Start Boost
is Fan/Pump
10.0 V
no Slip Comp
x.xxxx < y.yyyy
Start-Up
V/Hz
Enter value for
Break Voltage
10.0 Hz
x.x < y.y
Start-Up
V/Hz
Enter value for
Break Frequency
10.0 Hz
x.xxxx < y.yyyy
Start-Up
V/Hz
Enter value for
Max Voltage
10.0 V
x.x < y.y
1-30
Start-Up
Start-Up
V/Hz
V/Hz
Control selected
Control selected
is V/Hz/Custom
is V/Hz/Custom
no Slip Comp.
with Slip Comp.
Go to 0-1
Start-Up
1-23
Set #80 to
selection made
1-24
1-25
1-26
1-27
1-28
1-29
187