Allen-Bradley PowerFlex 70 Reference Manual page 179

Adjustable frequency ac drives
Hide thumbs Also See for PowerFlex 70:
Table of Contents

Advertisement

Figure 41 PowerFlex 70 & 700 Standard Control Option Startup (1)
Backup
Backup
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013
1-0
StartUp
1. Input Voltage
This step should
be done only
when "alternate
voltage" is
needed (see user
manual). It will
reset all drive
parameters with
specific choice
of Volts and Hz.
Enter
Rated Volts
>300?
Yes
No
1-1
1-2
StartUp
StartUp
1. Input Voltage
1. Input Voltage
Enter choice for
Enter choice for
Input Supply
Input Supply
400V, 50 Hz
208V, 60 Hz
<480V, 60 Hz>
<240V, 60 Hz>
Enter
Enter
1-3
StartUp
1. Input Voltage
Reset all
parameters to
their defaults?
<Yes>
No
Yes
1-4
StartUp
1. Input Voltage
Clear fault to
continue.
Basic Start Up (Input Voltage)
Backup
No
Fault Clear
Go to 0-1 (2)
Start-Up
179