Start-Up
194
Figure 56 PowerFlex 700 Vector Control Option Startup (8)
Flux Vector Start Up (Application Functions)
7-0
Start-Up
7.Appl. Features
This allows
programming of
additional drive
features.
7-1
Start-Up
7.Appl Features
Make a Selection
<Flying Start>
Auto Restart
Done
No
Process PI
7-3
7-2
Start-Up
7.Appl Features
Enter choice for
PI Reference
1
Analog In 1
7-3
Start-Up
7.Appl Features
Enter choice for
PI Feedback
1
Analog In 1
Start-Up
7-4
7.Appl Features
Enter value for
PI Setpoint
50.0%
xx.x < yy.y
Start-Up
7-5
7.Appl Features
Enter value for
PI Upper Limit
60.0 Hz
xx.x < yy.y
7-6
Start-Up
8.Appl Features
Enter value for
PI Lower Limit
-60.0 Hz
xx.x < yy.y
7-7
Start-Up
8.Appl Features
Enter value for
PI Integral Time
2.0 Secs
x.x < y.y
7-8
Start-Up
8.Appl Features
Select other PI
options in
parameter #124.
Go to 0-1 (8. Done/
Exit)
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013
Auto
Restart
Flying
Start
7-4
7-2
Start-Up
Start-Up
7.Appl Features
7.Appl Features
Enable Flying
Set Auto Restart
Start?
Tries to Zero to
<Yes>
disable the
No
function.
Yes
7-5
Start-Up
Start-Up
7.Appl Features
7.Appl Features
Enter value for
Enter value for
Flying StartGain
Auto Rstrt Tries
4000
0
xxx < yyyy
xxx < yyyy
Go to 7-1 (Auto
Auto Restart
Restart)
tries = 0?
Yes
Go to 7-1 (Done)
No
7-6
Start-Up
7.Appl Features
Enter value for
Auto Rstrt Delay
1.0 Secs
xx.x < yy.y

Hide quick links: