Numeric (Process) Measurement Definitions - Allen-Bradley Dynamix 2500 User Manual

Hide thumbs Also See for Dynamix 2500:
Table of Contents

Advertisement

Chapter 3
Setting Up Measurements
Table 28 - Transducer specification in mag & phase collection specification
Name
Accelerometer
92
The transducer specification in the Mag & Phase collection specification is
shown in the table below.
Base Unit
Input Type
Acceleration
ICP Accel
The filter specifications are shown in the table below:
Table 29 - Filter specifications in mag & phase measurement definitions
Name
Low Cutoff
1st Order
0.8 Orders
2nd Order
1.8 Orders
3rd Order
2.8 Orders
4th Order
3.8 Orders

Numeric (Process) Measurement Definitions

The Emonitor software and the Dynamix 2500 data collector support numeric
measurement definitions. This topic lists the unique characteristics of the
Dynamix 2500 data collector that you may need to know when setting up and
collecting numeric data.
Measurements Units Not Supported in the Dynamic 2500 Data Collector
• You can make a numeric measurement definition for any available
measurement unit by setting Data Type to 'Numeric.'
• Numeric measurement definitions with Input type set to 'DC Coupled'
with units not supported by the Dynamix 2500 data collector map to units
of USER (eus). The input type is part of the transducer specification that
you select for the collection specification. This results in a process (DC)
voltage measurement in the Dynamix 2500 data collector.
• For a list of support measurement units, see
page
74.
Full Scale Values for Numeric Measurements in the Dynamix 2500 data
collector
• The full scale value in the Dynamix 2500 data collector for a numeric
measurement is defined as ten times the value of the alarm or the baseline
measurement.
• If no alarm or baseline measurement exists for the measurement in the data
collector, the Dynamix 2500 data collector assumes a full scale value of
10,000.
Rockwell Automation Publication 1441-UM001B-EN-P - September 2012
Units
Calibration Value
g's
100
High Cutoff
Data collector filter type
1.2 Orders
None
2.2 Orders
None
3.2 Orders
None
4.2 Orders
None
Measurement Units on
DC Offset
0