Chapter 5
Collecting and Reviewing Data
164

Review Data

The Review Data screen lets you view the four types of measurements.
• Spectrum
• Time waveform
• Magnitude and phase orders
• Overall value
Follow these steps to the review data.
1. From the Route Manager, select a route and press Enter.
2. Press F1 (Review).
The Review Data screen appears.
Full scale range
Current signal
amplitude
Last recorded value
% changed from last
recorded value to the
current reading.
3. Press F2 (Next) or F1 (Previous) to move back and forth through the
review data screens.
Rockwell Automation Publication 1441-UM001B-EN-P - September 2012