Set Up An Offroute Cross Channel Phase Measurement - Allen-Bradley Dynamix 2500 User Manual

Hide thumbs Also See for Dynamix 2500:
Table of Contents

Advertisement

9. Add the two locations to a group list by double-clicking the Group column
in the Location pane.
The current group number appears in the Group column. Make sure you
assign the locations the same group number. The group is then loaded with
the list to the Dynamix 2500 data collector.
Cross Channel Phase Measurement Definitions on page 185
typical setup for a cross channel phase measurement.
Figure 8 - Cross Channel Phase Measurement Definitions
10. Connect the data collector to the computer and load the list to the
Dynamix 2500 data collector.
See
Load Selected Lists to the Data Collector on page 119
11. Once you have prepared the Dynamix 2500 data collector for data
collection, select the route and collect the cross channel phase
measurement.
See
Collect a Cross Channel Phase Measurement on page

Set Up an Offroute Cross Channel Phase Measurement

The Cross Channel Phase Offroute measurement is configured by creating a user-
defined measurement point. The Dynamix 2500 data collector keeps the user-
defined parameters until you collect another measurement point or press F2
(Default) on the Offroute User screen.
See
Create and Collect a User-defined Point on page 152
1. Select Data Collection from the Main Menu and press the Enter key.
The Data Collection screen appears.
2. Select the route. The Dynamix 2500 data collector always associates
Offroute measurements with a list.
Rockwell Automation Publication 1441-UM001B-EN-P - September 2012
Multi-channel Measurements
shows a
for details.
188.
for more information.
Chapter 6
185

Advertisement

Table of Contents
loading

Table of Contents