Chapter 5
Collecting and Reviewing Data
Table 43 - Offroute User Parameters
Parameter Name
Description
Change Name
Changes the name of the user-defined measurement point.
Select the hierarchy level for which you want to change the name. A
window opens at the bottom of the screen. Use the numeric key pad
to enter a new name and press F2 (OK).
Collection
The type of data to collect with this measurement.
Display Format
The display format of the measurement.
Units
The measurement units for the transducer.
The [S] designation refers to a static measurement that you must
manually enter with the numeric key pad. All dynamic measurements
and temperature process points require a transducer to make the
measurement.
Coupling
The type of coupling that will be applied to the measurement.
156
Rockwell Automation Publication 1441-UM001B-EN-P - September 2012
Values/Comments
Select Level (default)
Default Locn
Default Point
1 Horiz
Default
Overall/Signature (default): collect both a magnitude
reading and a signature.
Overall only: collect a magnitude reading only.
Signature only: collect a signature only.
RSS Overall: collect a digital overall measurement.
Spectrum (default)
Time
Phase
Order
Accel (G) (default)
gSE
RPM
A->V (mm/s)
Vel (IPS)
Vel (mm/s)
A->D (mil)
A->D (µm)
V->D (mil)
V-D> (µm)
Disp (mil)
Disp (µm)
Volts
EU's [S]
Temperature [S]
Current (A) [S]
Pressure (PSI) [S]
3
Flow (m
/s) [S]
Rot. Speed [S]
Linear Displ (mm)
Count [S}
Count Rate [S]
Volts [S]
Accel (G) [S]
Vel. (IPS) [S]
Vel (mm/s) [S]
Disp (mil) [S]
Disp (µm) [S]
AC: couples the input voltage signal.
DC: couples the input voltage signal.
ICP: (default) selects a standard ICP accelerometer
requiring a current source power supply