Allen-Bradley Dynamix 2500 User Manual page 112

Hide thumbs Also See for Dynamix 2500:
Table of Contents

Advertisement

Chapter 4
Loading and Unloading
Table 38 - Data Collector Advanced Settings Parameters
Parameter
Operating System
2CHEnable
Current Baud
Current Parity
Datapac Enumulation
Direction
Log Display
Machine Speed
Phone Number
Position
Sync Trigger Level
Sync Trigger Slope
112
7. Click OK to close the Data Collector Advanced Settings dialog box.
8. Click OK when finished.
Use the descriptions in this table to help you configure the parameters in the
Advanced Settings dialog box.
Description
Sets the operating system version of the data collector.
Enables the Emonitor software to download measurements
configured for 2-channel collection.
The baud rate for the serial communication.
or the USB this is the default.
The combination of parity, data bits and stop bits. The first
letter in the setting is the parity: None, Even, Odd. The first
number is the number of data bits. The second number is the
number of stop bits. N81 stands for no parity, 8 data bits, and 1
stop bit.
Configures the Dynamix 2500 Data Collector to collect data the
same as the Datapac.
The default direction to be used for Offroute measurements.
Display plots in log format in the data collector.
The default machine speed to use for Offroute measurements.
Not Used
The default position label to use for Offroute measurements.
The amplitude level for externally triggering the measurement.
This parameter is used when you set Trig Level to `Fixed' in the
Instrument Setup screen.
See
Configure the Data Collection Options on page
The input signal slope to be used for externally triggering the
measurement.
This parameter is used when you set Trig Level to `Fixed' in the
Instrument Setup screen.
See
Configure the Data Collection Options on page
Rockwell Automation Publication 1441-UM001B-EN-P - September 2012
Values
Yes
No
Recommend setting this to
115200.
The Dynamix 2500 data
collector uses only N81.
Yes
No
0 - None
1 - Horizontal
2 - Vertical
3 - Axial
Yes
No
1 to 16 characters
Positive
Negative
57.
Positive
Negative
57.