Follow these steps to take a spectrum measurement.
1. Attach the transducer to the current location.
2. From the Data Collection screen, press Enter.
The Route Manager Screen appears.
3. Select the spectrum route you uploaded from the Emonitor software and
press Enter to start your measurement for the current point.
Table 40 - Tasks Associated with Ranging the Measurement
If you
Previously collected a magnitude measurement
for the point
Set Auto Advance to On in the Instrument
Configuration screen
Set Auto Advance to Off
Set Fast Averaging to On in the Instrument
Configuration screen
Set Fast Averaging to Off
Figure 24 - Spectrum
Overall value
Cursor
Point information:
Machine name
Point ID
Point description
Alarm condition
Set cursor frequency
as running speed
Rockwell Automation Publication 1441-UM001B-EN-P - September 2012
Then
the spectrum measurement starts automatically
after you press Enter to accept the magnitude
reading
the Dynamix 2500 data collector automatically
goes to the next point in the list after it finishes
collecting the spectrum
then the Signature Measurement screen appears
the Dynamix collects the specified number of
averages before displaying the spectrum on the
screen
the Dynamix displays the spectrum while
collecting the averages
View / add coded
and type-in notes
Retake the
Leave without
measurement
storing data
Collecting and Reviewing Data Chapter 5
Current cursor frequency
and amplitude
Alarm indicators
Previous measurement
indicators
Percentage difference from
previous measurement