Chapter 2
Configuring the Dynamic 2500 Data Collector
Table 13 - Setup Screen Parameter Descriptions
Parameter
Description
Route Mem
Sets the location where the loaded route data is stored.
Timeout
The number of minutes the Dynamix 2500 data collector can remain idle
before it shuts itself off to conserve battery power.
Press On/Off to reactivate the instrument following a timeout. The
instrument returns to the point in the program where it was when it shut
off. No stored data will be lost.
Trigger
Sets the Phase/Order input trigger synchronization:
• Laser Tach enables the internal Laser Tachometer when a Phase or
Order measurement is collected.
• External uses the trigger input from the POWER/USB/TRIGGER
connector as the trigger source.
Dflt Units
Defines the units of measurement for Offroute standard velocity
measurements.
Important: Used only for Offroute standard velocity measurements.
Date Format
The format of the date displayed in the Dynamix 2500 data collector.
Time Zone
Sets the time zone.
Only used when using ActiveSync software data synchronization. The time
zone on the instrument must match the time zone on the computer. If you
are not using ActiveSync software then the time zone setting has no
effect.
Important: Always set your instrument to the correct time zone or your
files will not be in sync by time zone.
Date/Time
Displays the date and time in the format you select in the Date and Time
parameters.
Memory
Configures the memory:
• Select cmd to exit this field without selecting an option.
• Delete all routes and data from memory.
• Initialize formats the memory. Deletes all files from memory including
any route files and directories.
Important: These commands are performed on the memory location as
set by Route Memory.
Route Font
You can select the font size for the Route.
Envelope
The type of envelope to use for high frequency and rolling element bearing
analysis.
Determines which pre-defined measurement you can use to collect
Offroute data.
Navigation
Determines how the instrument navigates through the routes in the Data
Collection screens when the Right arrow key is pressed:
• Enpac- The instrument displays a Selection screen from which you
select the item you want to collect or review.
• DataPac - The instrument functions like a dataPAC 1500 in that it
automatically advances to the next point in the route.
56
Rockwell Automation Publication 1441-UM001B-EN-P - September 2012
Value
Internal (default)
Storage Card
Off (default)
5 min
10 min
15 min
20 min
External (default)
Laser Tach
English (ips) (default)
Metric (mm/s)
MM/DD/YYYY (default)
DD/MM/YYYY
YYYY/MM/DD
List of 30 time zones
Current data and time
Select cmd (default)
Delete all routes
Initialize
Big or Small
gSE (default), collects an Offroute gSE point.
ESP, collects an Offroute ESP point
Enpac
DataPac (default)