Commissioning

6.4 Changing password

Access to a submenu in the setup menu is gained by pressing the lock key
up key
and return to operator menu No. 1.
6.4
Changing password
The setup menu is password-protected in order to ensure that only authorized personnel can
make any changes in transmitter settings.
Change password as follows:
1. Press top up key
2. Enter password.
3. Use forward key
4. Press lock/unlock key
5. Use select key
6. Press lock/unlock key
7. Press top up key
See change password diagram (Page 76).
The factory-set password is 1000, but it can be changed to any value between 1000 and
9999.
Factory setting of password can be re-established as follows:
1. Switch off power supply.
2. While pressing top up key
3. Release top up key
6.5

Changing basic settings

In the basic settings menu it is possible to set the following parameters:
Parameter
Main frequency
Flow direction
Q
max
Q
max
Totalizer
Low flow cut-off
40
briefly to return to the previous menu. Press longer (2 sec.) to exit the setup menu
for 2 sec.
or backward key
and change key
two times to exit setup mode.
after 10 sec.
Description
Selection of main power supply frequency corresponding to the country in
which the flowmeter is installed (e.g. 60 Hz in America).
Selection of correct flow direction in pipe.
Setting of measuring range, analog outputs and frequency output. Also
individual dimension-dependent setting of value, decimal point, unit and time.
2
Setting of measuring range, analog outputs and frequency output. Also
individual dimension-dependent setting of value, decimal point, unit and time.
This menu is only visible if chosen as external digital input.
Setting of unit and decimal point.
Setting of a percentage of selected Q
reducing fluctuations in display and all outputs.
to reach password menu.
to unlock password.
to change password.
to confirm new password.
- switch on power supply.