Kemppi FastMig Pulse 350 Operating Manual page 18

Hide thumbs Also See for FastMig Pulse 350:
Table of Contents

Advertisement

Crater 4T Timer
Creep Start
ADVANCED FUNCTIONS
WisePenet
Penet%(123A)
WiseFusion
WiseFusion%
EN
MatchLog Menu
—> MinilogLevel
SYSTEM CONFIG MENU
Water Cooling
Cable Length
FineCalib
System Clock
Device
Information
16
FastMig Pulse 350, 450
On or OFF
Factory setting is OFF
10 – 99%
1% steps. OFF, CURVE (OFF =
100%)
ON or OFF
-30 ... +30 %
Factory setting: 0 %
ON or OFF
10 – 60 % or
Factory setting is CURVE
CURVE
-99 ... +125
Factory setting: 20 %
Water Cooler control:
Factory setting: AUTO
OFF / AUTO / ON.
Cable length: 10m –
Factory Setting: 10m
100m, 5m steps.
Fine Tuning
Factory Setting: 1.0V/100A
Calibration Point:
0.0V/100A –
10V/100A,
0,1V steps.
System Clock Settings
System Device information:
DevSW: Unit Software Version.
SysSW: System Software Version (Base software version).
BootSW: Boot Software Version.
SW Item: Software Item Number (IFS number).
Serial: Device Serial number.
Prog: Programmer name
Date: Programming date.
ON: if 4T is selected crater filling will last
at least time that has been ad-justed by
CraterTime or as long as trigger is pressed.
OFF: if 4T is selected crater filling will last as
long as trigger is pressed.
Factory setting is CURVE (Creep Start value
comes from Welding program).
Penetration control selection
Wise penetration percent setting. Set
penetration Current.
WiseFusion selection
When WISE FUSION is ON it controls the
amount of short circuits in the arc. The
lower the value there will be less short
circuits in the arc. The higher the value
there will be more short circuits in the arc.
Set the "MiniLog level"
OFF: Water Cooler always OFF.
AUTO: Water Cooler automatic control
ON. Water Cooler starts when welding
starts and is turned off after a delay when
welding stops.
ON: Water Cooler is always ON.
Welding cable loop length setting for
optimising arc control.
Compensation for varying cable resistance.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastmig pulse 450

Table of Contents