Kemppi FastMig Pulse 350 Operating Manual page 16

Hide thumbs Also See for FastMig Pulse 350:
Table of Contents

Advertisement

DOUBLE PULSE MIG
WFSpeed
WFS-Max
WFS-Min
FineTuning
FineTuningMax
FineTuningMin
Dynamics
Pulse Current
DPulseAmp
EN
DPulseFreq
WISEROOT / WISETHIN
WFSpeed
WFS-Max
WFS-Min
BaseCurrent
BaseCurrentMax
BaseCurrentMin
FormingPulse
FormingPulseMax
FormingPulseMin
StartTime
StartVoltage
* Different welding programs may further restrict the value range further.
MMA PROCESSES
Current
CurrentMax
CurrentMin
ArcForce
StartPower
14
FastMig Pulse 350, 450
0.7 – 25 m/min *
-9.0 ... +9.0
Factory setting is 0.0
( = curve point)
0.5 steps
-9.0 ... +9.0
0.5 steps
-9.0 ... +9.0
0.5 steps
-9 ... +9
Factory setting is 0
-10% ... +15%
Factory setting
is 0%
0.1 – 3.0 m/min
Factory setting is
CURVE
0.4 – 8.0 Hz
Factory setting is
CURVE
0.7 – 14 m/min *
-50 ... +50
-50 ... +50
1% steps
-50 ... +50
1% steps
-30 ... +30
-30 ... +30
1% steps
-30 ... +30
1% steps
-9 ... +9
Factory setting is 0
-30 ... +30
Factory setting is 0
14 – 350A/450A
14 – 350A/450A
14 – 350A/450A
-9 ... +9
Factory setting is 0
-9 ... +9
Factory setting is 0
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
Set the limit for maximum WFSpeed
Set the limit for minimum WFSpeed
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
Set the limit for maximum arc length
Set the limit for minimum arc length
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%
Adjusts the amplitude of the WFSpeed in 0.1 m/min
steps. Value comes from Welding program.
Adjusts the frequency of the double pulse in 0.1 Hz
steps. Value comes from Welding program.
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
Set the limit for maximum WFSpeed
Set the limit for minimum WFSpeed
Adjusts the base current of the curve – the arc length –
within certain limits.
Set the limit for maximum "arc length"
Set the limit for minimum "arc length"
Adjusts the forming pulse current of the curve in certain
limits. In other words, it controls arc pressure.
Set the limit for maximum forming pulse current
Set the limit for minimum forming pulse current
Set how long arc behaves like normal synergic MIG/
MAG prosess after the arc start. It gives heat for the arc
start.
Set the arc voltage which is used during StartTime.
In other words, it adjusts the length of the arc during
StartTime.
Welding current
Set the limit for maximum current value
Set the limit for minimum current value
Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Adjusts arc ignition