Kemppi FastMig Pulse 350 Operating Manual page 19

Hide thumbs Also See for FastMig Pulse 350:
Table of Contents

Advertisement

Restore Settings
Licence Menu
WeldData Delay
Display Delay
Pre Gas Time
Post Gas Time
Control
RemoteAutoRecog
MIG CurrentDisp
© Kemppi Oy / 1515
User 1 (one of ten users) Channel:
Selected user can restore to his backup memory channels one by one.
Other users' memory channels remain untouched.
Setup settings remain untouched.
User 1 (one of ten users) All Channels:
Selected user can restore all of his backup memory channels (0-9) at one time.
Other users' memory channels remain untouched.
Setup settings remain untouched.
Restore To Factory:
All channels (of all users) are removed.
All users' backup channels are removed.
All setup settings are set to defaults.
Licence Code allows you to enter the licence code:
- Up/Down arrows are used to select the code number position.
- Pulse encoder is used to select the code number (0-255) to be entered.
- Soft key button on the right is used to activate the licence number (after all numbers have been
entered). In case the code was wrong the earlier view will be displayed.
Licence Timers allows you to check the remaining time of the time-based Wise features.
Adjustment Range:
Factory Setting: 20s.
1s – 60s,
1s steps.
Adjustment Range:
Factory Setting: 10
1 – 20,
1 steps.
Pre Gas Time setting:
Factory Settings: CURVE
0.0s – 9.9s – CURVE,
0.1s steps.
Post Gas Time setting:
Factory Settings: CURVE
0.0s – 9.9s – CURVE,
0.1s steps.
Remote Control
Factory Settings: USER
Selection: USER /
PANEL / REMOTE /
GUN.
Remote Auto
Factory Setting: ON
Recognition: ON / OFF.
ON / OFF
Factory Setting: OFF
Defines how long the Weld Data is
displayed after Welding Ends.
Weld Data display is also turned off when
pulse encoder is turned or any button is
pressed.
Defines how long time the information is
displayed (like: "Setting Saved" text). This is
not always the exact time.
CURVE: Pre Gas time is read from the
Welding program.
0.0 – 9.9s: User Pre Gas time setting.
CURVE: Post Gas time is read from the
Welding program.
0.0 – 9.9s: User Post Gas time setting.
This setting affects to Welding panel (PF65
panel) remote control unit selection.
USER: PF65 user can freely select the
Remote control device.
PANEL: PF65 user can not select the remote
device. Selection is locked to PANEL.
REMOTE: Selection is locked to HAND
REMOTE device.
GUN: Selection is locked to GUN REMOTE
device.
ON: Remote control units are recognized.
Welding panel (PF65) jumps to PANEL
selection if the selected remote control
unit disappears. If PF65 USER selection is
allowed (see Control).
OFF: Remote control units are not
recognized. Remote device selection
remains unchanged if the selected remote
control unit disappears
ON: Display's amperage (A) preset values
OFF: Display's wire feed speed m/min.
EN
17