Individual settings
Fig. 48: Setting the needle guard (2)
(1) - Looper tip
(2) - Needle eye
To set the needle guard:
1. Loosen the screw (3).
2. Adjust the height of the needle guard accordingly.
3. Tighten the screw (3).
4. Loosen the screws (4).
Fig. 49: Setting the needle guard (3)
(4) - Screws
5. Move the needle guard up to the needle tip.
6. Tighten the screws (4).
Important
The needle must not be pushed aside any more than is required!
Service Instructions 610-10/630-10 - 01.0 - 12/2016
(3) - Screw