Code
Type
2488
Error
2901
Error
3010
Error
3011
Error
3012
Error
3020
Error
3021
Error
3022
Error
3030
Error
3104
Warning
4440
Error
–
4459
6000
Error
–
6299
6351
Error
–
6354
6360
Warning
6361
Warning
6362
Error
–
6367
134
Possible causes
Software error
Referencing timeout
Control: 100 V voltage error
Control: 100 V voltage error
Control: 100 V voltage error (I²T)
Short circuit in 24 V input or output • Check the connections
Short circuit in 24 V input or output • Check the connections
Short circuit in 24 V input or output
(I²T)
Sewing motor phase error
• Foot pedal not in rest position
• Setpoint device defective
OP3000 control panel:
Internal error
Internal error
Control defective (I²C)
Data on machine ID not permissible • Replace the control
Machine ID not connected
Internal EEprom
Remedial action
• Perform reset
• Perform software update
• Contact Customer Service
• Switch off and on the machine
• Check the clamping of the stepper
motor
• Check the connections
• Replace the control
• Check the connections
• Replace the control
• Switch off and on the machine
• Check the connections
• Replace the control
• Replace the control
• Replace the control
• Switch off and on the machine
• Check the connections
• Replace the control
• Test sewing motor phases
(R = 2.8Ω, high impedance to PE)
• Replace the encoder
• Replace the sewing motor
• Replace the control
• Do not step on the foot pedal when
starting up the machine
• Replace the setpoint device
• Switch off and on the machine
• Perform software update
• Replace the control panel
• Switch off and on the machine
• Perform software update
• Contact Customer Service
• Replace the control
• Check the connection of the
machine ID cable
• Replace the machine ID
• Replace the control
• Replace the control
Service Instructions 610-10/630-10 - 01.0 - 12/2016