DURKOPP ADLER 610-10 Service Instructions Manual page 108

Hide thumbs Also See for 610-10:
Table of Contents

Advertisement

4. Press On/Off.
 The tension element is closed.
5. Measure the tension value. It must be at 300 g.
Fig. 92: Calibrating the needle thread tension
(1) - Adjusting nut
(2) - Tension disks
If it is not at 300 g, correct as follows:
6. Loosen the threaded pin (3).
7. Press On/Off.
 The tension element opens.
8. Very gently turn the adjusting nut (1):
9. Select Tension Top 300g again.
10. Press On/Off and measure the tension value.
11. At the point at which the thread tension measurement device displays
12. Press On/Off.
 The tension element opens.
To set calibration position 2:
1. Select Tension Top 150g.
2. Change the thread tension with +/-1 or +/-10, until the thread tension
3. Exit the menu item.
To set calibration position 1:
1. Select Tension Top 5g.
2. Change the thread tension with +/-1 or +/-10, until the thread tension
3. Exit the menu item.
106
• Decrease value = turn clockwise
• Increase value = turn counterclockwise
a value of 300 g:
Tighten the threaded pin (3) without changing the position of the adjust-
ing nut (1).
measurement device displays 150 g.
measurement device displays a value.
(3) - Threaded pin
Service Instructions 610-10/630-10 - 01.0 - 12/2016
Programming

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

630-10

Table of Contents