Troubleshooting
Code
Type
2474
Error
2475
Error
2477
Error
2478
Error
2479
Error
2480
Error
2481
Error
2482
Error
2483
Error
2484
Error
2485
Error
2486
Error
2487
Error
Service Instructions 610-10/630-10 - 01.0 - 12/2016
Possible causes
Software error
Magnet wheel search
Stepper motor overload (I²T)
Encoder error
Current sensor:
• Stepper motor card defective
• Control defective
Direction of rotation
Error in the reference run
Stepper motor current error
Stepper motor overcurrent
Software error
Stepper motor insulation error
Software error
Software error
Remedial action
• Perform reset
• Perform software update
• Contact Customer Service
• Check the connection
• Test stepper motor phases
(R = 2.8 Ω, high impedance to PE)
• Replace the encoder
• Replace the stepper motor
• Replace the control
• Remove the cause of the stiff
movement or blockage
• Replace the stepper motor
• Replace the control
• Check the connection of the encoder
cable and replace, if necessary
• Replace the control
• Replace the control
• Replace the encoder
• Check plug assignment and change,
if necessary
• Check wiring in machine distributor
and change it, if necessary
• Test stepper motor phases and
check for correct value
• Replace the reference switch
• Remove the blockage
• Check the encoder cable and
replace, if necessary
• Replace the stepper motor
• Replace the sewing motor cable
• Replace the stepper motor
• Replace the control
• Perform reset
• Perform software update
• Contact Customer Service
• Check motor phase and PE for
low-impedance connection
• Replace the encoder
• Replace the stepper motor
• Perform reset
• Perform software update
• Contact Customer Service
• Perform reset
• Perform software update
• Contact Customer Service