Individual settings
Fig. 20: Positioning the needle
(1) - Edge of the thread take-up disk
(2) - Ring
To position the needle:
1. Lock the machine in place at position E ( p. 27).
2. Loosen the threaded pin (3) of the ring (2) and turn the ring (2) accordingly.
3. Tighten the threaded pin (3).
4. Remove the lock ( p. 27).
Service Instructions 610-10/630-10 - 01.0 - 12/2016
(3) - Threaded pin
35