As20Wrf/Brf Thermostat Withakl01/04/06Prf Or Akl08Rf Wiring Center - Salus SG888ZB System Manual

Wireless controls
Hide thumbs Also See for SG888ZB:
Table of Contents

Advertisement

Section 5
AS20WRF/BRF Thermostat with AKL01/04/06PRF or
AKL08RF Wiring Center
To begin pairing, all of the required
components are to be powered: AS20WRF/
BRF Thermostat, AKL Wiring Center and
AX10RF Receiver configured RX1 for boiler
demand (optional) . The Network Status LED
on the AKL Wiring Center should be flashing
and, if the AX10 RF Receiver is used, the red
backlight behind the Auto/Manual switch
should also be flashing .
1 . Press and hold the lighted red button on
the AC10RF Coordinator for 5 seconds,
until the LED begins flashing, to begin
pairing . When the network status LED on
the AKL Wiring Center and the backlight
on the Auto/Manual button of the AX10RF
Receiver (if used) stop flashing, they have
been paired and you are ready to pair the
AS20WRF/BRF Thermostat .
If the network status LED on the AKL Wiring Center continues blinking, turn off the power to
the device for 10 seconds.
2 . Once the network status LED on the
AKL Wiring Center is no longer flashing,
press the pairing button on the AC10RF
Coordinator for two seconds . Zone LED
on the Wiring Center will illuminate the ID
number of the device (see ID# key below)
Device Pairing & Setup without Internet
AKL Wiring Center ID Number Key
ID #
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6
1
2
3
4
5
6
7
8
9
0
5 .2

Advertisement

Table of Contents
loading

Table of Contents