7. On Display handset (DH) use soft key
calibration.
8. On Remote handset (RH) use Autotest to start the last step of calibration.
9. On Display handset (DH) press Escape to return to screen. The Remote handset
(RH) briefly displays that calibration was successful, and then shows ready state.
5.9.2

Coaxial Cable

Calibration must be performed if:
During the last 7 days no calibration has been performed. The user receives a
message, informing him that a field calibration is required.
The test adapter has been changed.
A patch cord has been changed.
For calibration with COAX adapters, the LanTEK
changed. Since the coaxial cables are tested at low frequencies, the additional data
received during calibration are largely ignored, thus calibration with LanTEK
is already completed after one step.
NOTE:
The LanTEK®III Cable Tester COAX adapters are equipped with BNC connections. COAX
cables applied by the user must convert from/to BNC and F (CATV) or other plug types.
1.
Open "Cable Type" on start screen.
2. Use Arrow Keys to navigate to option
3. Use Arrow Keys to navigate to desired cable type and confirm with Enter.
4. Connect Coax adapters to Display handset (DH) and Remote handset (RH).
5. Connect the short coaxial calibration cable to the adapters of Display handset
(DH) and Remote handset (RH).
6. Use Arrow Keys to navigate on ready screen to "Calibration" and press Enter.
LanTEK III
User Manual
Fig. 61 Open Patch Cord
Fig. 62 Calibration Complete
III process, consisting of 4 steps, is
®
Ethernet and confirm with
to start the last step of
II Cable Tester
®
Enter.
161809 Iss 2