Implemented Functions And Service Access Points (Sap; A.2.5 Read Diagnostic Information - Festo CPV..-DI01 series Electronic Manual

Valve terminal with direct connection
Hide thumbs Also See for CPV..-DI01 series:
Table of Contents

Advertisement

A. Technical appendix

A.2.5 Read diagnostic information

Slave_Diag
Set_Prm
A.2.6 Implemented functions and service access points (SAP)
A−12
The diagnostic data are requested by the CP system via the
function Slave_Diag (see section 3.3.4, Diagnosis via PROFI
BUS−DP).
With the function Set_Prm you have the possibility of deter
mining the watchdog time (WD_Fact_1, Octet 2, WD_Fact_2,
Octet 3). In the event of a fault, the CP system will switch off
all the valves and electric outputs after the parametrized
time (e.g. if there is a bus failure).
Function
Data_Exchange
RD_Inp
RD_Outp
Slave_Diag
Set_Prm
Chk_Cfg
Get_Cfg
Global_Control
Set_Slave_Add
Tab. A/6:
Overview of implemented functions and service
access points
Available
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Festo P.BE−CP−DI01−EN en 0503d
Destination SAP
(DSAP)
NIL
56
57
60
61
62
59
58
55