A. Technical appendix
A.2.2 Send parametriziung data
Set_Prm
Octet 1: Station status
Bit
Meaning
0
1
2
3
WD_On
4
Freeze_Req
5
Sync_Req
6
Unlock_Req
7
Lock_Req
Tab. A/1:
Octet 1: Station status
Festo P.BE−CP−DI01−EN en 0503d
The parametrizing data are transferred from the DP master
to the valve terminal with the function Set_Prm.
Explanation
Reserved
Response monitoring of the CP system on/off:
0 = off
1 = on
0 = FREEZE mode not requested by the master
1 = FREEZE mode set by the master
0 = SYNC mode not requested by the master
1 = SYNC mode set by the master
Bit 7
Bit 6
Explanation
0
0
min T
SDR
0
1
CP system released for other masters
1
0
CP system blocked for other masters
1
1
CP system released for other masters
+ slave parameter may be overwritten
A−7