1. Installation
Total current consumption The table below shows how to calculate the total current
1−32
consumption for a CP system. The values specified have been
rounded up.
Current consumption of CP electronics
(pin 1)
CPV Direct
CPV valve terminal
CPA valve terminal
CP input module
Sensors
CP output module
Carry forward
Current consumption of valve supply
(pin 2)
Current consumption of
all simultaneously
1)
energized valve coils
1)
Current consumption depends on the valve type (see Technical
specifications for the valves in the relevant pneumatics manuals).
Tab. 1/14: Calculating the total current consumption
Max. 100 mA
Max. 40 mA
20 mA
Max. 40 mA
See manufacturer's
specifications
Max. 40 mA
__x_____mA
Festo P.BE−CP−DI01−EN en 0503d
Sums
=_______mA
=_______mA