6. Commissioning ABB CS31

6.2.2 T200 / 07CS61 as bus master

Extension to the
CP system
CP system
CPV Direct
(without extension)
CPV Direct +
CP input module
CPV Direct +
CP valve terminal or
CP output module
CPV Direct +
CP input module +
CP valve terminal or
CP output module
l = Line number
n = Set station number
Tab. 6/2:
Overview of module identifiers
Festo P.BE−CP−DI01−EN en 0503d
Four CS31 system buses can be connected to the T200 sta
tion. The coupler type 07CS61 plugged in nearest to the T200
CPU has line number 1, the subsequent buses have line
numbers 2, 3 and 4.
Example:
Signal designation O 1.20,05 means:
line 1, CS31 bus address 20, output 05.
Within the framework of program creation, the CPU must be
informed of the configuration on the relevant lines. In order to
do this, use the programming system (e.g. 07 PC 332) to
enter the appropriate module identifiers in the configuration
table. The following table provides an overview.
Module identifier
with coupler
with coupler
07CS61
O16
IO16
O16
O16
IO16
O16
Signal designation
Outputs
O l.n,00 ... O l.n,15
O l.n,16 ... O l.n,31
O l.n,00 ... O l.n,15
O l.n+1,00 ... O l.n+1,15
O l.n,16 ... O l.n,31
O l.n+1,00 ... O l.n+1,15
Inputs
I l.n,00 ... I l.n,15
I l.n,00 ... I l.n,15