Mendota ML39 Assembly, Installation And Operating Instructions page 73

Fullview direct vent gas fireplace heater
Table of Contents

Advertisement

Operating Instructions
1. Read the above safety information carefully before proceeding.
2. Do not attempt to light the pilot by hand; the door must remain on this unit during pilot ignition.
3. Press the ON/OFF button on remote control to begin the ignition sequence.
The fireplace will emit an audible beep then the igniter will begin to spark. After the pilot lights and is established, the valve will
automatically open and the burner will light. The burner will initially light to full flame. Adjust it to an appealing setting with the
remote. See Remote Operating Instructions in Operating Instructions Manual.
Warning: If the pilot fails to light, the system will "lockout". Press ON/OFF button on remote control to Turn Off the system
and reset the "lockout". Allow five minutes for any gas in the unit to dissipate before attempting to re-light the pilot.
4. Press ON/OFF button on remote control again to start ignition sequence.
5. If the fireplace will not operate, follow the instructions "To Turn off Gas to Fireplace" below and call your service technician or
gas supplier.
To Turn Off Gas to Fireplace
1. Press the ON/OFF button on the remote control.
2. Turn off CPI Pilot Mode from remote control.
3. Turn OFF the external manual shutoff valve if was required and supplied by installer and mounted adjacent to fireplace.
4. Turn OFF the internal manual shutoff valve located in the fireplace under the front right access panel.
5. Turn OFF all electric power to the fireplace if service is to be performed.
85-03-01136
ML39
Page 73