Mendota FV34 Installation And Operating Instructions Manual

Mendota FV34 Installation And Operating Instructions Manual

Decor fullview direct vent gas fireplace heater

Advertisement

MODEL NO. FV34 DECOR FULLVIEW DIRECT VENT GAS FIREPLACE HEATER
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result causing property damage, personal injury or
loss of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gasses, unless a
certified kit is used.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and must be installed.
Installation and Operating Instructions
AA-11-03017
85-03-01107-H
AVERTISSEMENT. Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incendie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs
ou liquids inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
Cet appareil peut être installé dans une maison
préfabriquée (É.-U. seulement) ou mobile déjà installée à
demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de
gaz indiqués sur la plaque signalétique. Une trousse de
conversion est fournie avec cet appareil.
Une barrière conçue pour réduire le risque de brûlures
du verre chaud est fournie avec cet appareil et doit être
installée.
FV34 DECOR

Advertisement

Table of Contents
loading

Summary of Contents for Mendota FV34

  • Page 1 Installation and Operating Instructions MODEL NO. FV34 DECOR FULLVIEW DIRECT VENT GAS FIREPLACE HEATER AA-11-03017 WARNING: If the information in these instructions AVERTISSEMENT. Assurez-vous de bien suivre les is not followed exactly, a fire or explosion may instructions données dans cette notice pour réduire au...
  • Page 2: Hot Surfaces Are Normal

    See chapter Instructions. Read and 2.1.1 Mendota Fireplace Curing follow all instructions given in this Chapter and perform the 3-step curing cycle. After the 3-step curing cycle has been completed, all smoking will have stopped. Some slight odors may remain. With subsequent use of this Fireplace, odors will slowly dissipate and disappear.
  • Page 3: Table Of Contents

    1.3 H ........2 URFACES ARE ORMAL 1.4 P ..2 ERIODIC AND ANNUAL CLEANING ARE REQUIRED 2.1 SAFETY AND WARNING INFORMATION ....5 3.2.5.3.1 Mendota Cool Wall 33 2.2 S ..........6 AFETY ARNINGS 3.2.5.3.2 Versiheat 3.2.5.3.3 FlexHeat 2.3 R .
  • Page 4 5.6 IPI CPI M ..........77 ODES 5.7 H ? ..77 O CHANGE FROM ELSIUS TO AHRENHEIT 5.8 F ......78 IRST IGHTING NSTRUCTIONS 5.9 O ........78 PERATING NSTRUCTIONS 5.10 T ......78 AS TO IREPLACE 4.11 V ............
  • Page 5: Safety And Warning Information

    Building Permit & Inspection Requirements All installations of Mendota Fireplaces must comply with all the requirements stated in this Installation and Operating Manual. The dealer and/or installer must obtain all required building permits and inspection approvals from the local building inspection department or the local jurisdiction.
  • Page 6: Safety Warnings

    HIGH-ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7,500 ft., understand the need for gas input derating. Contact your local gas company to see if your gas type is already derated for your altitude or contact Mendota Technical Service for support.
  • Page 7 Never obstruct the flow of combustion and ventilat ion air. Keep the front of the fireplace clear of all obstacles and materials for servicing and proper operation. Use only Mendota approved Screens, Fronts and Trim Kits. Due to high temperature, the fireplace should be located out of traffic areas and away from furniture and draperies.
  • Page 8 été plongée dans l’eau. Do not use any fronts or doors with this fireplace unless they are certified by Mendota and installed by a certified installer.
  • Page 9: Requirements For Thec

    A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation 85-03-01107 FV34 DECOR Page 9...
  • Page 10: General Technical References

    If ignition system goes into lockout mode, always wait 5 minutes before attempting to re-light. Never block off convection air openings or paths. Trim panels or surrounds shall not seal ventilation openings in the fireplace. Always use Mendota decorative fronts and Mendota approved vent systems and vent caps only. Keep the flue warm...
  • Page 11 ATTENTION It is important that the blower is turned on during this step to prevent the curing smoke from staining the wall finish above the fireplace. Mendota recommends completing Step 1 prior to install ation of wall finish materials. Visible smoke and strong odor are to be expected during this step. If desired, disable smoke alarms before this step, smoke from the initial curing c ycle will set off smoke alarms.
  • Page 12: Mechanical Technicalr

    3.2 MECHANICAL TECHNICAL REFERENCES Planning the installation This Mendota Fireplace must be installed and serviced by a qualified installer, service agency, or the gas supplier. When planning on appliance installation, it is necessary to determine the following information before installing: •...
  • Page 13 The listing label is in the air gap below the Fireplace. It is secured to a chain and left loosely in the air gap and can be pulled out to be viewed. Figure 3-1 Listing Label 85-03-01107 FV34 DECOR Page 13...
  • Page 14 A few warnings and caution labels are attached to this appliance body and door glass as required per code to inform you of important facts. Make certain you heed all the warning and caution statements during installation and maintenance of this appliance. Figure 3-3 Figure 3-2 Figure 3-5 Figure 3-4 Figure 3-7 Figure 3-6 Figure 3-8 85-03-01107 FV34 DECOR Page 14...
  • Page 15 Figure 3-9 Figure 3-10 85-03-01107 FV34 DECOR Page 15...
  • Page 16 FV34 DECOR Fireplace Ratings Information This Mendota Fireplace can be installed directly on top of a metal, masonry or wood structural surface. ELECTRICAL REQUIREMENTS: 120 Volts AC, 1.5 Amps (minimum line voltage allowed 110 Volts AC) REQUIRED GAS SUPPLY PRESSURE: NAT.
  • Page 17 HINT: To greatly reduce surface temperatures surrounding this Fireplace during operation, Mendota recommends operating the integrated convection air blower which aid in cooling all surrounding surfaces. Mendota Fireplaces comply with ANSI Z21.88-2017 Standards for maximum surface temperatures (ambient plus 117 F) on exposed “combustible”...
  • Page 18 2". If this fireplace is raised off the floor more than 6", 40-5/8" MIN No hearth protection pad is required. ROUGH FRAMING NON COMBUSTIBLE FACING WIDTH Figure 3-13 Corner Installation Dimensions 85-03-01107 FV34 DECOR Page 18...
  • Page 19 Fireplace Features Identification below. Identify the features included with this Fireplace and their locations. Figure 2-14 Fireplace Features Diagram , Figure 3-14 Fireplace Features Diagram 85-03-01107 FV34 DECOR Page 19...
  • Page 20 Convection Blower System A blower is provided as standard equipment with this FV34 DECOR Fireplace. The blower has an air output rating of 95 CFM (in free air). This Fireplace is designed to operate with the blower turned off or on. Turning the blower on aids in distributing and circulating heat to the room this Fireplace is installed in.
  • Page 21 If the appliance is being installed on a cement slab, a layer of plywood may be placed underneath this fireplace to prevent conducting cold up into the room. 49-7/8" FLOOR WALL THIMBLE CENTER 37" FINALIZED HEIGHT Figure 3-16 FINALIZED FRAMING DIMENSIONS 85-03-01107 FV34 DECOR Page 21...
  • Page 22 16”, the resulting clearance will be reduced by 50% 18" HEARTH PAD to 8” between the heat source and the R-1 Rated wall board. STUDS 36 3 4 " ROUGH FRAMING HEIGHT 85-03-01107 FV34 DECOR 24 3 4 Page 22 MINIMUM FINISH UNIT BASE TO RO...
  • Page 23 12" x (1/1) + 12" = 24" above the convection air opening The top of the top convection air opening is 24-3/4” up from floor level. Figure 3-20 APPROVED MANTEL CHART Figure 3-19 MANTEL CLEARANCES 85-03-01107 FV34 DECOR Page 23...
  • Page 24 If these materials are used it is recommended t hat the fireplace is raised at least 12” above the floor. Mendota does not guarantee any materials used around the fireplace. Mendota disclaims any and all liability for any damage to finishing materials including warping, discoloring, cracking, peeling or flaking.
  • Page 25 If the hearth pad being used is thicker than the dimension “A” the fireplace will need to be raised. For example, if the distance “A” from the bottom of the fireplace to the bottom guide is 1 1/2" and the hearth pad being used is 4” thick the fireplace would need to be raised 2 1/2”. 85-03-01107 FV34 DECOR Page 25...
  • Page 26 1”. This is the depth of the finishing guides on the fireplace and will result in the best final appearance. Mendota does not guarantee any materials used around the fireplace. Mendota disclaims any and all liability for any damage to finishing materials including warping, discoloring, cracking, peeling or flaking.
  • Page 27 Ceramic or Porcelain Tile Use of ceramic or porcelain tiles as facing materials around a Mendota fireplace is approved. If selecting a mosaic tile where tiles are held together with a webbing, ensure the webbing is a non-combustible material like fiberglass. Also ensure that the tiles are not attached to the webbing with a glue or epoxy that will off gas and smell when heated.
  • Page 28: Paint Types Approved For Use

    Mendota fireplaces. Mendota further cautions that proper adhesives be used to attach stone facings. Pay attention to the potential of off gassing of chemical vapors from mastic and other adhesives.
  • Page 29 Please read the following instruction before installing the finishing material on the front of this fireplace. If you have any questions about finishing the fireplace, contact a Mendota dealer or the Mendota Service Department. • To prevent damage, remove any decorative front, screen, or door from the fireplace and mask the fireplace...
  • Page 30 This option allows the front to mount with any finish material. The front will fit inside the guides. Allowing the front to be recessed into the wall. If you are unsure of which option to use this option as there are no restrictions on the type of finishing material that can be used. 85-03-01107 FV34 DECOR Page 30...
  • Page 31 Many television manufacturers specify in their installation instructions that the television must not be installed near or above a heat source. The decision to install a television near or above a Mendota fireplace rests solely on the consumer. It is the consumers responsibility to satisfy television specifications and insure the television will not exceed maximum operation temperatures.
  • Page 32 Recommendation 3: Install a heat transfer system Mendota Hearth offers three heat transfer systems that take heat from the fireplace and redirect it to another area. When used correctly these heat transfer systems can make it possible to mount a television above the fireplace without installing a mantel or creating a recessed cavity.
  • Page 33: Mendota Cool Wall

    Mendota Cool Wall The Mendota Cool Wall system uses natural convection to take heat off the wall directly above the fireplace and redirects it up and away from surrounding areas. Testing has shown that when using a Cool Wall system, temperatures above the fireplace are reduced making it possible to mount a television 15”...
  • Page 34: Versiheat

    Because the Versiheat system must be running to reduce temperatures the fireplace cannot be operated during a power outage. Testing has shown that when using two Versiheat systems temperatures above the fireplace are reduced making it possible to mount a television 15” above the fireplace’s top air gap. 85-03-01107 FV34 DECOR Page 34...
  • Page 35: Flexheat

    Because the FLexHeat system must be running to reduce temperatures the fireplace cannot be operated during a power outage. Testing has shown that when using the FlexHeat system temperatures above the fireplace are reduced making it possible to mount a television 12” above the fireplace’s top air gap. 85-03-01107 FV34 DECOR Page 35...
  • Page 36 The FV34 DECOR Fireplaces requires coaxial rigid- 4” diameter exhaust & 6-5/8” diameter air inlet and approved vent caps for most installations. All UL Listed Coaxial Rigid 4” x 6-5/8” Vent pipe components and vent caps are approved for use. Do not mix components of different brands or series.
  • Page 37 Flue Venting Components Identification Diagrams Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions. ITEM DESCRIPTION 6" or 7” PIPE (DuraVent 6”/Amerivent 7”), 9”, 12” 12" VENT STACK 24"...
  • Page 38 VERTICAL TERMINATION APPROVED APPROVED APPROVED VERTICAL RISE THREE HORIZONTAL DISCHARGE TRIPLE 90° ELBOWS 90° ELBOWS APPROVED w/ RESTRICTIONS VERTICAL TERMINATION VERTICAL RISE TRIPLE 90° ELBOWS HORIZONTAL TERMINATION APPROVED APPROVED APPROVED Figure 3-23 Approved Vent Systems 85-03-01107 FV34 DECOR Page 38...
  • Page 39 (45 cm) minimum ) Clearance to inside corner - 12 inches (30 cm). Minimum 24” horizontal clearance to any surface, Vinyl surfaces require 24” min (60 cm). such as an exterior surface, for vertical terminations. 85-03-01107 FV34 DECOR Page 39...
  • Page 40 Alternatively, you may also vertically extend the wood burning flue liner up 24” higher than the top surface of the gas appliance vent cap. Figure 3-24 Side by Side Vent Caps 85-03-01107 FV34 DECOR Page 40...
  • Page 41: Lectrical Echnical Eferences

    Place connected wire ends within junction box then close and secure the junction box cover plate. AC Power Connection STEP 1 STEP 2 STEP 3 Figure 3-26 Wire Connections 85-03-01107 FV34 DECOR Page 41...
  • Page 42 Instruct homeowner to retain the DC battery pack and the connecting harness in a safe and secure place for use during power outages Figure 3-28 BACKUP DC POWER INLET Figure 3-27 Backup DC Power Junction Box Installation Figure 3-29 DC Backup Power Connection 85-03-01107 FV34 DECOR Page 42...
  • Page 43 Label all wires prior to disconnection when servicing control. not installed nor used. Wiring Errors can cause improper and dangerous operation. Replacement wires must have the same type and size of Verify proper operation after servicing. insulation as the original. 85-03-01107 FV34 DECOR Page 43...
  • Page 44: Lumbing Technical References

    TRAIN. ADHERE STRICTLY TO LOCAL AND NATIONAL CODES. Gas Supply Line Sizing This Mendota Gas Fireplace comes equipped with a 1/2" N.P.T. Female inlet. Gas supply piping must enter the Fireplace cabinet on the left side. Use the table, below, to determine the proper gas line diameter that must be installed to run from the supply regulator to the factory installed manual shutoff valve.
  • Page 45 Local requirements supersede all other codes. Figure 3-33 Keyed Manual Gas Shutoff Valve 85-03-01107 FV34 DECOR Page 45...
  • Page 46 The gas inlet fitting supplied with this Fireplace provides a 1/2” female NPT fitting. This requires you to supply a ½” NPT male fitting for connection to this appliance. Based on the gas line size you have selected use an appropriate NPT fitting to adapt and connect to the 1/2” male NPT end adapter. 85-03-01107 FV34 DECOR Page 46...
  • Page 47 This appliance has been converted for use at an altitude of: Orifice size: Manifold Pressure: Input (Btu/h): Fuel Type: Date of conversion: Converted by: Cet appreeil a été converti au ____ Injecteur ________ Pression à la tubulure d'alimentation _____________ Déoit calorifique ______________ 85-03-01107 FV34 DECOR Page 47...
  • Page 48: Installation Checklist

    ❑ Adjust exhaust damper to match vertical chimney length. See 3.11.1 Vent Damper Adjustments ❑ Co-axial vent rigid pipe, wall vent cap or roof vent cap is installed by a Mendota approved serviceperson in accordance with instructions. ❑ All joints are secured, "twist-locked" and leak-proof.
  • Page 49: Unpacking The Fireplace

    Lift the outer box vertically straight upward until lower edge of the box clears the top of the unit body. Set the box aside. Mendota recommends recycling the outer box. Figure 4-1 Outer Box Removal 85-03-01107...
  • Page 50: Contents Of The Manual Packet

    Once the outer box is removed, you will find the Fireplace body and a manual packet white box. This manual packet white box includes the items shown in the table, below. Contact Mendota Technical Service if any parts are missing.
  • Page 51: Ending Up The Shipping Clips

    3. Remove screw driver. Insert screw driver tip into one hole in clip. Lift screw driver up. To break clip off, repeat up down motion of screw driver seven to eight times. Figure 4-4 Shipping Clip STEP 1 & STEP 2 STEP 3 Figure 4-6 Bend Up Clip 2 Figure 4-5 Bend Up Clip 1 85-03-01107 FV34 DECOR Page 51...
  • Page 52: O Remove Door

    Use the tool provided to connect the spring latches to the glass frame. Insert tool into hole in spring latch, pull latch towards you, rotate latch so the hook is facing downward then release latch to hook to door frame. Door is now connected and sealed to unit. 85-03-01107 FV34 DECOR Page 52...
  • Page 53 3. Next, see diagrams, below. Install the light lens base gasket, light lens, light lens retainer bracket and the four retaining 10-24 nuts. Warning: Use a 3/8” hex hand driver to tighten nuts.DO NOT over tighten the nuts. Doing so can crack the light lens. Figure 4-8 Accent Light Bulb & Lens Installation 85-03-01107 FV34 DECOR Page 53...
  • Page 54: Natural Gas To Lpg Conversion

    Figure 4-9 HA-58-00410 LP Kit Parts Orifice sizes requirement A Natural Gas to LPG conversion kit #HA-58-00410 must be ordered and installed to convert the FV34 DECOR Fireplace to burn LPG. LP Conversion Kit # HA-58-00410 contains the following parts: One motorized LP pressure regulator #907.012 and one cap orifice #65-14-00052(drill #52”) and an L-shaped Torx wrench.
  • Page 55 See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG. Figure 4-10 Remove Burner Airbox 85-03-01107 FV34 DECOR Page 55...
  • Page 56 CAUTION: Always use one 7/16” open end wrench and one large pliers or vice grips tool to hold, loosen and tighten pilot hood base to prevent damage to pilot mount bracket. Figure 4-13 Pilot Orifice Selection Figure 4-14 Pinch Pilot Base with Vice Grips Figure 4-12 Pilot Body 85-03-01107 FV34 DECOR Page 56...
  • Page 57 When installing the burner airbox, make certain not to damage the pilot flame sensor or sparker. Make certain the burner is properly level and aligned with the rectangle cutout in the burner airbox. 85-03-01107 FV34 DECOR Page 57...
  • Page 58 The pilot light flames must be a minimum of 1” long and must overlap the propagation ports on the burner. Verify that the burner tubes ignite quickly and the burner flames propagate smoothly along the entire length of the burners. Figure 4-16 Pilot Flames 85-03-01107 FV34 DECOR Page 58...
  • Page 59: Venting

    Fireplace. Oversights or failure to conform to all installation requirements will void the applicable warranty. The FV34 DECOR Fireplace must be vented to the outside and must use a rigid coaxial ducting system. This heater must be properly connected to a venting system in accordance with the manufacturer' s installation instructions.
  • Page 60 36 in. High Altitude Installation Information 18’ 48 in. Prior to installing at altitudes higher than 7500, please contact the Mendota technical service 60 in. department for specific venting requirements and venting restrictions. 5 ft. - 17 ft. Maximum Horizontal Run 17ft.
  • Page 61 = 8 feet. Using 90 Elbows A. The FV34 DECOR Fireplace by MENDOTA allows maximum flexibility in the use of 90 elbows in the vent system. The length of the first straight vertical section directly connected to the fireplace’s starter collar determines the maximum horizontal run and the number of 90 elbows allowed for this fireplace.
  • Page 62 MINIMUM (18”) RISE HORIZONTAL TERMINATION The FV34 DECOR Fireplace must be installed by a qualified Mendota approved serviceperson. A Maximum Horizontal Run allowed is 6 inches if an 18” vertical starter section and one 90-degree elbow is connected directly to this fireplace’s flue starter collar.
  • Page 63 Never allow the vent to run downward. This will cause high temperatures and the possibility of a fire. This FV34 DECOR Fireplace must be installed by a qualified Mendota service person Position fireplace in desired location. See 2.2.16.5 Exterior Vent Locations and Restrictions for guidelines on proper vent cap placement on exterior of home.
  • Page 64 Figure 4-19 DUAL 90 DEG ELBOWS APPROVED Figure 4-20 TRIPLE 90 DEG ELBOWS 85-03-01107 FV34 DECOR Page 64...
  • Page 65 The FV34 DECOR Fireplace must be installed by a qualified Mendota approved serviceperson. 1. Place the fireplace in its desired location. Drop a plum bob from the ceiling to the position of the fireplace flue exit. Mark the location where the vent will penetrate the ceiling.
  • Page 66 9,10 40 FEET 1,2,3,4,5 MAX. 85-03-01107 FV34 DECOR Page 66...
  • Page 67 Mendota has spent considerable time and effort in the design of this fireplace and its venting system. Through this effort, Mendota has been able to certify the use of Four 90 elbows when terminating vertically.
  • Page 68 1/8” and turn clockwise to close the vent damper, release. The base of the damper adjustment rod has a pointer that indicates the position of the damper. 85-03-01107 FV34 DECOR Page 68...
  • Page 69: Log Set/ Media Installation

    4.12 LOG SET/ MEDIA INSTALLATION Four distinctive wood species log sets, natural river rocks, tumbled marble and four distinctive glass media are available as options for this model Insert. Select one or multiple media options. Consult with your Mendota dealer. Driftwood Log Set 5.
  • Page 70: Lighting Checklist

    ☐ DO NOT proceed with operation unless burner cycles "on/off" without delays and the flame is "stable" and not "lifting" off burner after 5 minutes of initial ignition. Caution: If ignition system goes into lockout mode , be sure to wait a minimum of five minutes b efore re- lighting. 85-03-01107 FV34 DECOR Page 70...
  • Page 71 IMPORTANT: Try each new shutter setting approx. ½ hr. before mak ing additional changes. NOTE: Changes in burner flame can be made by re-arranging the coals and media and burner air shutter opening. 85-03-01107 FV34 DECOR Page 71...
  • Page 72: Aesthetic Considerations

    We are committed to quality and satisfaction for all Mendota owners. Thank you for choosing a Mendota to be a source of comfort and beauty in your home.
  • Page 73 (Note: If you do not hear any beeps when you press the sync button, contact your Mendota dealer or installer for assistance.) Within seven seconds, press the “on” button on the remote control. The fireplace will beep four times to indicate that the remote control’s command is accepted and sets to the particular code of that controller.
  • Page 74 3. Up/Down Button: This button is used to increase or decrease the thermostat temperature, flame height, fan speed, and accent light intensity. Mode Selection Button: This button is used to toggle between the various function icons: flame height, fan speed, accent light. 85-03-01107 FV34 DECOR Page 74...
  • Page 75: Instructions

    Understanding Your Remote-Control Icons Your remote control displays and controls the following functions. See below for detailed control explanations. Note: the “AUX On” function is not used in this fireplace. Figure 5-4 Remote Control Icons 85-03-01107 FV34 DECOR Page 75...
  • Page 76 Once you set the desired light intensity, the system will remember your selection until you manually change it. Rear Burner: This function is not available for this fireplace. Skip through this icon. 85-03-01107 FV34 DECOR Page 76...
  • Page 77: Ipi And Cpi Modes

    Note: The snowflake icon will be visible on the display at all times when in CPI mode. Recommended: Mendota recommends that CPI mode is used during the winter months ° when the average daily high temperature falls below 50 F.
  • Page 78: Irst Time Lighting Instructions

    5.10 TO TURN OFF GAS TO FIREPLACE 1. Press the ON/OFF button on the remote control. 2. Turn off CPI Pilot Mode from remote control. Turn off the internal manual shutoff valve in the appliance. See 0 85-03-01107 FV34 DECOR Page 78...
  • Page 79 Local requirements supersede all other codes. Figure 3-33 Keyed Manual Gas Shutoff Valve 85-03-01107 FV34 DECOR Page 79...
  • Page 80 4. Turn OFF the external manual shutoff valve if one was required and supplied by installer and mounted adjacent to fireplace. 5. Turn OFF all electric power to the fireplace if service is to be performed. 85-03-01107 FV34 DECOR Page 80...
  • Page 81: Frequently Asked Questions

    Where can I find the model and serial numbers? When requesting service, you will be asked to provide the model number and serial number to your Mendota dealer. This information will expedite the warranty verification process. The Listing Label contains the model number and serial number for your particular appliance.
  • Page 82 3” to 12” long area) and the gasket adhesive in no longer functional to stick to glass, then replace the gasket. Visually inspect the vent terminal (vent cap) for leaves, twigs and other debris accumulation. Clean if required. 10. Clean door glass. 11. Clean enamel firebox lining, if one is installed. 85-03-01107 FV34 DECOR Page 82...
  • Page 83 These adjustments should be made by a qualified technician to achieve the best flame performance. Contact your installer or Mendota dealer if you feel your fireplace is not burning correctly. Improper setup and adjustment is not covered under warranty.
  • Page 84 This should clear the lockout mode. Turn on the remote and start the fireplace. Ensure the master switch is in the run/on position. After completing these steps, contact your Mendota dealer if fireplace won’t turn on. What happens when I first light my fireplace? When you first light your fireplace, the initial curing phase is initiated.
  • Page 85: Required Periodic Inspections

    Check joints between the gasket pieces at the corners. They should butt against each other to create a seal. Gaps between gasket pieces can cause exhaust leaks and lead to acrid smell concerns. 85-03-01107 FV34 DECOR Page 85...
  • Page 86: Ilot Outage And R E -Lighting

    If you are using a “backyard” Natural Gas well as the gas source, you must submit formal gas analysis data sheets to Mendota Fireplaces for review and calculation of proper main burner orifice sizes prior to first firing. It is known that unpurifi ed Natural Gas from “backyard” wells can contain high energy levels causing over firing.
  • Page 87: Replacement Parts Information

    Electrical Junction Box: An electrical junction box is located on the right side of this appliance and is accessible through the Convection Blower and Control Module access panel. Gas Supply Inlet connection: The main gas supply line enters this appliance on the left side and is accessible through the Gas Valve Inspection Panel. 85-03-01107 FV34 DECOR Page 87...
  • Page 88 Gas Train Replacement Parts List Please contact your Mendota Dealer for parts availability and parts pricing. 85-03-01107 FV34 DECOR Page 88...
  • Page 89 GROMMET, RUBBER 50-03-00067 NUT, 10-24 KEPS, ZINC PLATED 50-01-00156 HHSMS, #8-18 X 1/2" TYPE AB, BLACK ZINC 15-02-00121 BLOWER Figure 6-3 FV34 DECOR BLOWER ASSEMBLY Burner System Parts Item # Part Number Description HA-78-00287 Burner Assembly Figure 6-4 BURNER WELDMENT...
  • Page 90 Accent Light Replacement Parts Figure 6-5 Accent Light Bulb & Lens Installation Figure 6-6 Accent Light Lens Installation 85-03-01107 FV34 DECOR Page 90...
  • Page 91: To Replace Damaged Glass

    The glass frame assembly and its individual components are available through Johnson Gas Appliance Company. Contact your dealer for more detailed ordering information. GLASS FRAME ASSEMBLY REPLACEMENT PARTS LIST ITEM PART NUMBER DESCRIPTION FRAME, WELDMENT, GLASS, FV34 DECOR HA-58-00262 GASKET, TADPOLE, 5 /8” BULB, 3/4” TAIL, 110” 65-02-00103 65-06-01184 GLASS, CERAMIC, FV34 DECOR...
  • Page 92: Final Installation And Homeowner Checklist

    ❑ Burner flames are “stable” and are not “lifting” off burner. ❑ Inform owner that an initial curing step is required. Read and follow Mendota Fireplace and Insert Curing Instructions (found on unit and in owner’s manual). Smoke will emit during initial curing step.
  • Page 93: Warranty Policy Statement

    7.2 WARRANTY POLICY STATEMENT Mendota Fireplace, a division of Johnson Gas Appliance Company, extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
  • Page 94 Owner accepts that this appliance requires close monitoring of children and vulnerable individuals who are in the vicinity of this appliance when it is in operation. Mendota does not assume or accept any liability claims for burns or other physical or material damages resulting from touching hot glass surface and hot metal surfaces that are part of this appliance or other adjacent object such as hearth pads and mantels that may heat up during operation of this appliance.
  • Page 95 How to Obtain Warranty Service If you discover a problem that you believe to be covered by the warranty, you must report to your Mendota Dealer within 30 days, with proof of purchase, purchase date, model name and serial number.
  • Page 96 Owner Registration After installation, Mendota fireplace owners must register with Mendota to qualify for the Lifetime Limited Warranty within 30 days. Product registration will activate your Lifetime Limited Warranty. Owners should complete the forms available at: mendotahearth.com/warranty Note: Your Mendota dealer can assist with warranty applications and information.
  • Page 98 Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids, Iowa 52405 Mendota Warranty Registration...

This manual is also suitable for:

Aa-11-03017

Table of Contents