Ipi And Cpi Modes; Instructions - Mendota ML39 Assembly, Installation And Operating Instructions

Fullview direct vent gas fireplace heater
Table of Contents

Advertisement

5.7 IPI AND CPI MODES

Intermittent Pilot and Continuous (Standing) Pilot Features
This gas fireplace is equipped with an electronic ignition system that first lights a pilot then uses the pilot to ignite the main
burners. The pilot can be set in the CPI (Continuous Pilot Ignition) mode to allow the pilot to remain on indefinitely by setting
the remote control to CPI mode. If the remote control is set to the IPI (Intermittent Pilot Ignition) mode, the pilot will only light
and remain ON while the main fireplace burners are operating.
IPI Mode: This mode turns the pilot off when the fireplace is not functioning and only lights the pilot automatically when a call
for heat is made by the remote control.
CPI Mode: If set to CPI mode, the pilot will ignite and remain on always.
Setting to IPI or CPI mode
With the remote control OFF, press the MODE button. You will see either "CPI" or "IPI"
displayed on the screen. Press the Up-arrow button to set "CPI" mode and press the
DOWN arrow button to set "IPI" mode. Once set to the desired setting, press ON/OFF
button to activate the fireplace.
Note: The snowflake icon will be visible on the display at all times when in CPI mode.
Recommended: Mendota recommends that CPI mode is used during the winter months
when the average daily high temperature falls below 50
chimney heated for proper updraft during burner ignition, and it will also eliminate excessive condensation of exhaust vapors
on the door glass. Leaving the fireplace in CPI mode will keep the fireplace body warm and eliminate cold drafts and heat loss to
the cold air that is trapped inside the firebox.
5.8 FIRST TIME LIGHTING INSTRUCTIONS
Warning: If you do not
follow these instructions
exactly, a fire or
explosion may result
causing property
damage, personal injury,
and loss of life.
Safety Information
This fireplace is equipped with an ignition device which automatically lights the pilot. Do not attempt to light pilot by hand.
Before operating, smell all around fireplace area for gas. Be sure to smell next to the floor because some gas is heavier than air
and will settle on the floor.
Toggle Master Switch to ON. Remote control will not communicate to receiver unless the Master Switch is ON.
Use only the supplied remote control to light the pilot. This valve will not operate if the pilot is not lit and stable.
Do not use this fireplace if any part has been underwater. Immediately call a qualified service technician to inspect and replace
any component which has been under water. Attempted operation may result in fire or explosion resulting in property damage,
personal injury, and loss of life.
85-03-01136
°
F. This will keep the fireplace
WHAT TO DO IF YOU SMELL GAS
Do not light any appliance.
Do not touch any light switch
Do not use any phone in your building.
Call your gas supplier from a neighbor's phone.
Follow the provider representative's instructio ns.
If you cannot reach your gas supplier, call the fire
department for assistance.