Igbt Module V6 - Kemppi FASTMIG X 450 Service Manual

Hide thumbs Also See for FASTMIG X 450:
Table of Contents

Advertisement

1.2 IGBT module V6

DIODE TEST:
Diodes must be measured both forward bias and reverse bias condition to make sure they are fine
Check the diodes using the multimeter diode function to measure their threshold voltage 0,3...0,6 V
When measuring IGBT unit diodes you must disconnect other end (X7) of main transformer
DC link (+)
DC link (-)
Measurings:
Positive test lead
X20
X7
X20
X6
X13
X16
X15
X16
Kemppi OY
X16
X20
Negative test lead
X7
X20
X6
X20
X16
X13
X16
X15
SERVICE MANUAL
FASTMIG X
Result
0,3-0,7VDC
no value
0,3-0,7VDC
no value
0,3-0,7VDC
no value
0,3-0,7VDC
no value
28 (37)