8.1.2. IGBT module V1

IGBT module can be tested by multimeter if using the diode tester function. Module holds six diodes and in many
cases they may be defective if IGBT is damaged
When measuring IGBT unit diodes you must disconnect other end of main transformer (X7)
After measuring connect other end (X7) back
o
Measurings:
1) Positive test pole (1, red) to connector X16, negative test pole (1, black) to connectors X7, X8 and X14 one at time
Result: 0,3...0,6 diodes Ok
2) Negative test pole (2, black) to connector X13, positive test pole (2, red) to connectors and X7, X8 and X14 one at time
Result: 0,3...0,6 diodes Ok