Primary Rectifier V5 - Kemppi FASTMIG X 450 Service Manual

Hide thumbs Also See for FASTMIG X 450:
Table of Contents

Advertisement

1.1 Primary rectifier V5

Primary side primary rectifier diodes can be measured one at the time
Diodes must be measured both forward bias and reverse bias condition to make sure they are fine
Check the diodes using the multimeter diode function to measure their threshold voltage 0,3...0,6 V
Measurings:
Positive test lead
X1, X2, X3 (one at time)
X16
X20
X1, X2, X3 (one at time)
Kemppi OY
SERVICE MANUAL
FASTMIG X
X16
X1
X2
X3
Negative test lead
X16
X1, X2, X3 (one at time)
X1, X2, X3 (one at time)
X20
X20
Result
0,3-0,7VDC
no value
0,3-0,7VDC
no value
27 (37)