2. SECONDARY RECTIFIER CARD Z003

Use a digital multimeter to test the secondary unit diodes. Diodes are in groups, so you can measure them in four
separate groups
Disconnect main transformer secondary side wires from Z003 card
Remember to test diodes both ways: forward bias and reverse bias
Measurings:
Positive test lead
X1
X2
X3
X4
Z003, heatsink
Z003, heatsink
Z003, heatsink
Z003, heatsink
Kemppi OY
SERVICE MANUAL
FASTMIG X
Negative test lead
Result
Z003, heatsink
0,3-0,7VDC
Z003, heatsink
0,3-0,7VDC
Z003, heatsink
0,3-0,7VDC
Z003, heatsink
0,3-0,7VDC
X1
no value
X2
no value
X3
no value
X4
no value