Connector
Description
X1:1
+5V (tacho)
X1:2
GND (tacho)
X1:3
Tacho-signal
X2
Panel connector
X3:1
+50V
X3:2
Not connected
X3:3
Motor (+), KWF Sync
X3:4
Not Connected
X3:5
GND
X3:6
Current sense, sub feeder
X3:7
Sub feeder ID
X3:8
+9V
X3:9
Motor voltage
X3:10
EMF-control
X3:11
Tacho signal, sub feeder
X3:12
Motor voltage control
X4:1
GND, Remote control
X4:2
Start:Potentiometer, Torch line 2
X4:3
Not connected
X4:4
Potentiometer 2, Remote control
X4:5
Start:Potentiometer, Torch line 1
X4:6
+5V, Remote control
X4:7
Not connected
X4:8
System bus DATA
X4:9
System bus DATA
X4:10
Gas valve, GND
X4:11
Potentiometer 1, Remote control
X4:12
Gas valve (+)
X4:13
Not connected
X4:14
System bus GND
X4:15
System bus +50V
X5:1
System bus +50V
X5:2
System bus DATA
X5:3
System bus GND
X6:1
Door switch (+)
X6:2
Door switch (-)
X7
JTAG (production programming)
X8
Memory card connector
X9
Chassis ground
X11
Spool space heater (+)
X12
Spool space heater (-)
X14:1
External start
X14:2
GND
X14:3
ARC ON signal output
X14:4
Remote control WFS
X14:5
Remote control U
X14:6
+5V, Remote control
X15:1
Motor 2+
X15:2
Motor 1-
X15:3
Motor 1+
X15:4
Motor 2-
X15:5
System bus +50V