8. SYSTEM CARD A003
System card in FastMig X 450 is to make possible MMA welding without separate wire feed unit
•
System card is connected to power source via CAN bus with connector X1
•
8.1. Power supply
Connector X6 is the only one which is connected to this card. There are +50DC bus and CAN bus in this connector. DC-
•
DC converter generates +5Vdc in this card by transformer T2. Regulator N3 generates 3,3Vdc.
8.2. Leds
8.3. Connectors
Kemppi OY
SERVICE MANUAL
FASTMIG X
Led
Description
H1
Blinking when there is another pro-
cessor or system device connected in
the CAN bus
H5
Aux. voltage + 5 Vdc
H6
Aux. voltage 3,3 Vdc
Connector
Description
X6:1
System bus +50V
X6:2
System bus DATA
X6:3
System bus GND
X7
JTAG (RD usage)
X8
Memory (RD usage)
X9
Chassis Ground
17 (37)