Alarm messages

Pluggable Module failure - protected

...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
PMcEQF
The respective pluggable module failed.
Equipment
equipment
Deferred
Reported
The red fault LED associated to the failed pluggable module is lit.
Hardware failure of the pluggable module.
Replace the failed module.
As no equipment protection exists for pluggable modules, PMcEQF, and
PMcUPF are always reported simultaneously as a reminder that a pluggable
module failure is service affecting.