Alarm messages
Remote Power Supply Open Circuit
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-124
RPScOPENC
No electric current is flowing through the electrical circuit in the remote power
supply box, connected to the SRU.
Equipment
equipment
Prompt
Reported
–
This can be caused by a blown fuse, faulty wiring, or missing components in
the remote power supply box or even by manually disconnecting the power
box.
Identify and repair the defective component in the power box.