Ms Near-End Background Block Errors Threshold Crossing 15-Min - Alcatel-Lucent 1643 AMS Operation Manual

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
STM-1 MS Near-end background block errors threshold
crossing 15-min
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
MS1NBBEcTHR15
The STM-1 Multiplex Section near-end background block errors counter
exceeded the provisioned threshold during a 15-minute monitoring period.
Quality of service (performance monitoring)
sdhMS
Information
Not Reported
Possible causes are:
Dirty optical connector(s).
Equipment fault(s) in the upstream station.
Check upstream external cabling or equipment.
Alcatel-Lucent - Proprietary
See notice on first page
1-173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1643 am

Table of Contents