Alarm messages

LAN unit failure - protected

...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
IPcEQF
®
The TransLAN
option board (X8PL or X4IP-V2) is defective.
Equipment
equipment
Deferred
Reported
The red fault LED on the unit is lit.
®
TransLAN
option board failure but a protection works.
Replace the TransLAN
As there is no equipment protection of the TransLAN
and IPcUPF are always reported simultaneously as a reminder that a hardware
failure is service affecting.
Alcatel-Lucent - Proprietary
See notice on first page
®
option board..
®
option board., IPcEQF