Alarm messages
Mandatory IS-IS parameters missing
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
DCNBUcLOST
The network element is isolated from the DCN because mandatory IS-IS
parameters are missing.
Processing error
dcn
Prompt
Reported
The red fault LED is lit.
Not all IS-IS parameters are correctly set for this mode.
Provision the IS-IS parameters correctly.
Alcatel-Lucent - Proprietary
See notice on first page