Alarm messages

SHDSL Near-end errored seconds threshold crossing 15-min

...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
1-136
SDSLNEScTHR15
The SHDSL near-end errored seconds counter exceeded the provisioned
threshold during a 15-minute monitoring period.
Transmission
sdsl
Prompt
Reported
Degraded connection - More ES than the allowed threshold (120) have been
detected in the current 15-minutebin.
Check SHDSL connection on attenuation and crosstalk.
The default values of the raise and clear thresholds are fix preset. They cannot
be changed by user provisioning.
Alcatel-Lucent - Proprietary
See notice on first page