Alarm messages

SHDSL Near-end severely ES threshold crossing 24-hrs

...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
SDSLNSEScTHR24
The SHDSL near-end severely errored seconds counter exceeded the
provisioned threshold during a 24-hour monitoring period.
Transmission
sdsl
Deferred
Reported
Severely Degraded connection - More SES than the allowed threshold (20)
have been detected in the current 24-hour bin.
Check SHDSL connection on attenuation and crosstalk.
The default values of the raise and clear thresholds are fix preset. They cannot
be changed by user provisioning.